Percutaneous Endovascular Left-Atrial Appendage Closure Devices for Stroke Prevention in Atrial Fibrillation

Policy Number: MP-490

Latest Review Date: May 2023

Category: Medical

POLICY:

The use of a device with U.S. Food and Drug Administration (FDA) approval for percutaneous left atrial appendage closure may be considered medically necessary for the prevention of stroke in individuals with atrial fibrillation when the following criteria are met:

  • There is an increased risk of stroke and systemic embolism based on CHADS2 or CHA2DS2-VASc score and systemic anticoagulation therapy is recommended; and
  • The long-term risks of systemic anticoagulation outweigh the risks of the device implantation.

The use of a device with FDA approval for percutaneous left atrial appendage closure for stroke prevention in individuals who do not meet the above criteria is considered investigational.

The use of other percutaneous left atrial appendage closure devices, including but not limited to the Lariat device, for stroke prevention in individuals with atrial fibrillation is considered investigational.

For Surgical Left Atrial Appendange Occlusion Devices for Stroke Prevention in Atrial Fibrillation, see MP 751.

DESCRIPTION OF PROCEDURE OR SERVICE:

Stroke prevention in individuals with atrial fibrillation (AF) is an important goal of treatment. Treatment with anticoagulant medications is the most common approach to stroke prevention. Because most embolic strokes originate from the left atrial appendage, occlusion of the left atrial appendage may offer a non-pharmacologic alternative to anticoagulant medications to lower the risk of stroke. Multiple percutaneously-deployed devices are being investigated for left atrial appendage closure. Two left atrial appendage devices (the Watchman and Amulet devices) have approval from the U.S. Food and Drug Administration for stroke prevention in patients with AF.

Atrial Fibrillation and Stroke

Atrial fibrillation (AF) is the most common type of irregular heartbeat, affecting at least 2.7 million people in the U. S. Risk of AF has been found to be lower in Black, Hispanic and Asian individuals relative to White patients, including following adjustment for demographic and AF risk factors. Stroke is the most serious complication of AF. The estimated incidence of stroke in nontreated patients with AF is 5% per year; despite a lower risk of AF, Black and Hispanic patients have an increased risk of stroke compared with White patients. Stroke associated with AF is primarily embolic, tends to be more severe than the typical ischemic stroke, and causes higher rates of mortality and disability. As a result, stroke prevention is a main goal of AF treatment.

Stroke in AF occurs primarily as a result of thromboembolism from the left atrium. The lack of atrial contractions in atrial fibrillation leads to blood stasis in the left atrium, and this low flow state increases the risk for thrombosis. The area of the left atrium with the lowest blood flow in atrial fibrillation, and, therefore, the highest risk of thrombosis, is the left-atrial appendage (LAA). It has been estimated that 90% of left-atrial thrombi occur in the LAA.

Treatment

Pharmacologic

The main treatment for stroke prevention in AF is anticoagulation, which has proven efficacy. The risk for stroke among patients with AF is evaluated using several factors. Two commonly used scores, the CHADS2 score, and the CHA2DS2-VASc score are described in Table 1. Warfarin is the predominant agent in clinical use. A number of newer anticoagulant medications, including dabigatran, rivaroxaban, and apixaban, have recently received U.S. Food and Drug Administration (FDA) approval for stroke prevention in nonvalvular AF and have demonstrated non-inferiority to warfarin in clinical trials. While anticoagulation is effective for stroke prevention, there is an increased risk of bleeding. Also, warfarin requires frequent monitoring and adjustments, as well as lifestyle changes. Newer agents do not require the frequent monitoring seen with warfarin therapy; however, specific reversal agents do not exist for all of these agents. Guidelines from the American College of Chest Physicians (2018, updated from 2012) recommend that CHA2DS2VASc be used to evaluate stroke risk, and patients initially identified as having a low stroke risk should not be given antithrombotic therapy. In addition, they recommend bleeding risk assessments be given to every patient at every patient contact and that “potentially modifiable bleeding risk factors” should be the initial focus.

Table 1. CHADS2 and CHA2DS2-VASc Scores to Predict Ischemic Stroke Risk in Patients With Atrial Fibrillation

Letter

Clinical Characteristics

Points Awarded

C

Congestive heart failure (signs/symptoms of heart failure confirmed with objective evidence of cardiac dysfunction)

1

H

Hypertension (resting blood pressure >140/90 mmHg on at least 2 occasions or current antihypertensive pharmacologic treatment)

1

A

Age ≥75 y

2

D

Diabetes (fasting glucose >125 mg/dL or treatment with oral hypoglycemic agent and/or insulin)

1

S

Stroke or transient ischemic attack (includes any history of cerebral ischemia)

2

V

Vascular disease (prior myocardial infarction, peripheral arterial disease, or aortic plaque)

1

A

Age 65-74 y

1

Sc

Sex category of female (female sex confers higher risk)

1

Adapted from Lip et al (2018), and January et al (2014).

Bleeding is the primary risk associated with systemic anticoagulation. Risk scores have been developed to estimate the risk of significant bleeding in patients treated with systemic anticoagulation. An example is the HAS-BLED score, which has validated to assess the annual risk of significant bleeding in patients with AF treated with warfarin. The score ranges from zero to nine, based on a number of clinical characteristics, including the presence of hypertension, renal and liver function, history of stroke, bleeding, labile international normalized ratios (INRs), age, and drug/alcohol use. Scores of three or greater are considered to be associated with high risk of bleeding, potentially signaling the need for closer monitoring of the patient for adverse risks, closer monitoring of INRs, or differential dose selections of oral anticoagulants or aspirin.

Surgery

Surgical removal, or exclusion, of the LAA is often performed in patients with atrial fibrillation who are undergoing open heart surgery for other reasons. Percutaneous LAA closure devices have been developed as a nonpharmacologic alternative to anticoagulation for stroke prevention in atrial fibrillation. The devices may prevent stroke by occluding the LAA, thus preventing thrombus formation.

Several versions of the devices have been developed. The PLAATO system (ev3 Endovascular) was the first device to be approved by the FDA for LAA occlusion. The device was discontinued in 2007 for commercial reasons, and intellectual property was sold to manufacturers of the Watchman system. The WATCHMAN® left atrial appendage system (Boston Scientific, Maple Grove, MN) is a self-expanding nickel titanium device. It has a polyester covering and fixation barbs for attachment to the endocardium. Implantation is performed percutaneously through a catheter delivery system, utilizing venous access and transseptal puncture to enter the left atrium. Transesophageal echocardiography and fluoroscopy are used to guide the procedure. Following implantation, patients are anticoagulated with warfarin or alternate agents for approximately one-two months. After this period, patients are maintained on antiplatelet agents (i.e., aspirin and/or clopidogrel) indefinitely.  The Watchman FLX device is a next-generation Watchman device that is also FDA-approved for LAAC. This device is based on the design of the Watchman device, is fully recapturable and repositionable, and was made to occlude a wider size range of LAA than the original Watchman device. A second-generation device, the Amplatzer Amulet, has also received FDA approval and has been developed for the specific indication of LAAC. The Amplatzer Amulet consists of a nitinol mesh disc to seal the ostium of the LAA and a nitinol mesh distal lobe, to be positioned within the LAA. The device is preloaded within a delivery sheath. The Amplatzer cardiac plug (St. Jude Medical, Minneapolis, MN), is FDA-approved for closure of atrial septal defects but not for LAA closure. The Percutaneous LAA Transcatheter Occlusion (PLATTO) device (eV3, Plymouth MN) has also been studied for this purpose but has not received FDA approval. The Occlutech™ (Occlutech, Sweden) Left Atrial Appendage Occluder (has received a CE mark for coverage in Europe. The Cardioblate™ closure device (Medtronic) is currently being tested in clinical studies.

The Lariat Loop Applicator is a suture delivery device approved by the FDA, intended to close a variety of surgical wounds. It is not specifically approved for LAAC. While the Watchman and other devices are implanted in the endocardium, the Lariat is a non-implant epicardial device.

Outcome Measures

The optimal study design for evaluating the efficacy of percutaneous LAAC for the prevention of stroke in AF is a randomized controlled trial that includes clinically relevant measures of health outcomes. The rate of ischemic stroke during follow-up is the primary outcome of interest, along with rates of systemic embolization, cardiac events, bleeding complications, and death. For the LAAC devices, the appropriate comparison group could be oral anticoagulation, no therapy (for patients who have prohibitive risk for oral anticoagulation), or open surgical repair.

Ideally, percutaneous LAAC devices would represent an alternative to oral anticoagulation for the prevention of stroke in patients with AF, during the postimplantation period, the device may be associated with increased thrombogenicity and, therefore, anticoagulation is used during the periprocedural period. Most studies evaluating percutaneous devices have included patients who are eligible for anticoagulation.

KEY POINTS:

The most recent update with literature review covers the period of through March 23, 2023.

Summary of Evidence:

For individuals who have atrial fibrillation (AF) who are at increased risk for embolic stroke who receive an FDA approved percutaneous left atrial appendage closure (LAAC) device (e.g. Watchman or Amulet), the evidence includes RCTs and observational studies. The relevant outcomes are overall survival, morbid events, and treatment-related morbidity. The most relevant evidence comes from two industry-sponsored RCTs that compared the Watchman device with anticoagulation alone. One trial reported noninferiority on a composite outcome of stroke, cardiovascular/unexplained death, or systemic embolism after two years of follow-up, with continued benefits with the Watchman device after four years of follow-up. The second trial did not demonstrate noninferiority for the same composite outcome but did demonstrate noninferiority of the Watchman device to warfarin for late ischemic stroke and systemic embolization. Patient-level meta-analyses at five-year follow-up for the two trials reported that the Watchman device is noninferior to warfarin on the composite outcome of stroke, systemic embolism, and cardiovascular death. Also, the Watchman was associated with lower rates in major bleeding, particularly hemorrhagic stroke, and mortality over the long-term. Evidence for the Amplatzer Amulet device comes from 2 RCTs comparing the Amulet and Watchman devices, one of which was a short-term trial that assessed periprocedural outcomes at 45 days. The second trial comparing the Amulet and Watchman devices found the Amulet device to be noninferior to the Watchman device after 18 months of follow-up for a composite efficacy outcome that included ischemic stroke or systemic embolism and for a composite safety outcome that included all-cause mortality, major bleeding or procedure-related complications. One additional RCT evaluated the use of either the Amplatzer Amulet or Watchman device versus anticoagulants; subgroup analyses according to device were not performed. After up to 4 years of follow-up, the study found LAA closure with either the Watchman or Amulet was noninferior to anticoagulants for a composite outcome that included stroke, TIA, systemic embolism, clinically significant bleeding, significant periprocedural or device-related complications, or cardiovascular mortality. Among patients in which the long-term risk of systemic anticoagulation exceeds the procedural risk of device implantation, the net health outcome will be improved. The evidence is sufficient to determine that the technology results in an improvement in the net health outcome.

For individuals who have AF who are at increased risk for embolic stroke who receive a percutaneous LAAC device other than the Watchman device or Amplatzer Amulet device (e.g., Lariat or Amplatzer Cardiac Plug), the evidence includes several nonrandomized comparator studies and uncontrolled observational studies. Relevant outcomes are overall survival, morbid events, and treatment-related morbidity. One nonrandomized study that compared outcomes among patients undergoing LAAC with the Lariat device with patients receiving anticoagulant or antiplatelet therapy reported fewer thromboembolic events in the group receiving the Lariat device. Evidence from other observational studies of these devices which report high procedural success but also numerous complications. In addition, these devices do not have U.S. FDA approval for LAAC. The evidence is insufficient to determine that the technology results in an improvement in the net health outcome.

Practice Guidelines and Position Statements

American College of Chest Physicians

In 2018, the American College of Chest Physicians (CHEST) guideline made the following recommendation regarding left atrial appendage (LAA) occlusion and oral anticoagulation: "In patients with AF at high risk of ischemic stroke who have absolute contraindications for OAC [oral anticoagulation], we suggest using LAA occlusion (Weak recommendation, low-quality evidence)."

American Heart Association

The American Heart Association, in collaboration with the American College of Cardiology and the Hearth Rhythm Society (2019) published an  update of their guideline for the management of patients with atrial fibrillation. The recommendation in the guideline states: "Percutaneous LAA occlusion may be considered in patients with AF at increased risk of stroke who have contraindications to long-term anticoagulation." The class of recommendation is IIb and the level of evidence is B-NR (moderate quality of evidence, non-randomized). No other LAA closure devices are mentioned in the guideline.The AHA also released a scientific statement in 2021 about managing AF in patients with heart failure and reduced ejection fraction. They state that, "It is reasonable to consider LAA closure in patients with AF and heart failure with reduced ejection fraction (HFrEF) with moderate to high stroke risk and contraindications to long-term oral anticoagulation", however, they also note that the role of LAA therapies in patients with AF with HFrEF needs to be better understood, and this is an opportunity for future research.

U.S. Preventive Services Task Force Recommendations

Not applicable.

KEY WORDS:

Left Atrial Appendage Closure Device, WATCHMAN®, LARIAT®, AMPLATZER®, PLATTO, LAA, Amplatzer Cardiac Plug device, WaveCrest

APPROVED BY GOVERNING BODIES:

In 2002, the PLAATO system (ev3 Endovascular) was the first device to be approved by the U.S. Food and Drug Administration (FDA) for LAA occlusion. The device was discontinued in 2007 for commercial reasons and intellectual property was sold to manufacturers of the Watchman system.

In 2015, the Watchman™ Left Atrial Appendage Closure Technology (Boston Scientific) was approved by the FDA through the premarket approval process by the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients with Atrial Fibrillation randomized controlled trial. In 2020, the Watchman FLX device (Boston Scientific) was approved by the FDA based on the single-arm, nonrandomized PINNACLE FLX study. These devices are indicated to reduce the risk of thromboembolism from the LAA in patients with nonvalvular AF who:

  • Are at increased risk for stroke and systemic embolism based on CHADS2 or CHA2DS2-VASc scores and are recommended for anticoagulation therapy;
  • Are deemed by their physicians to be suitable for anticoagulation therapy; and
  • Have an appropriate rationale to seek a nonpharmacologic alternative to anticoagulation therapy, taking into account the safety and effectiveness of the device compared with anticoagulation therapy.

In August 2021, Abbott’s Amplatzer™ Amulet™ device was approved by the FDA through the premarket approval process to treat people with Atrial Fibrillation at risk of stroke.  This device is indicated to reduce the risk of thrombus embolization from the left atrial appendage in patients who:

  • Have nonvalvular atrial fibrillation and who are at increased risk for stroke and systemic embolism based on CHADS2 or CHA2DS2-VASc scores,
  • Are suitable for short term anticoagulation therapy, and
  • Have appropriate rationale to seek a non-pharmacologic alternative to oral anticoagulation, taking into consideration the safety and effectiveness of the device.

Several other devices are being evaluated for LAA occlusion but are not approved in the U.S. for percutaneous LAAC. In 2006, the Lariat ™ Loop Applicator device (SentreHEART), a suture delivery system, was cleared for marketing by the FDA through the510(k) process. The intended use is to facilitate suture placement and knot tying in surgical applications where soft tissues are being approximated or ligated with a pretied polyester suture. The Amplatzer Cardiac Plug device (St. Jude Medical) and WaveCrest™ (Johnson & Johnson Biosense Webster) have CE approval in Europe for LAAC but are not currently approved in the U.S. for this indication.

BENEFIT APPLICATION:

Coverage is subject to member’s specific benefits.  Group specific policy will supersede this policy when applicable.

ITS: Home Policy provisions apply.

FEP:  Special benefit consideration may apply.  Refer to member’s benefit plan. 

CURRENT CODING:

CPT Codes:  

For percutaneous LAA closure:

33340

Percutaneous transcatheter closure of the left atrial appendage with endocardial implant, including fluoroscopy, transseptal puncture, catheter placement(s), left atrial angiography, left atrial appendage angiography, when performed, and radiological supervision and interpretation.

 

REFERENCES:

  1. Abbot Press Release. Available online at: https://abbott.mediaroom.com/2021-08-16-Abbotts-Amplatzer-TM-Amulet-TM-Device-Approved-by-FDA-to-Treat-People-With-Atrial-Fibrillation-at-Risk-of-Stroke.
  2. Abbott Structural Heart Solutions.  Available online at: https://www.structuralheartsolutions.com/us/structural-heart-products-solutions/laa-amplatzer-amulet-occluder/overview/#isi. 
  3. Al-Kassou, BB, Omran, HH. Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure. Biomed Res Int, 2017 Nov 1;2017:1519362.
  4. Alli O, Doshi S, Kar S et al. Quality of life assessment in the randomized PROTECT AF (Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation) trial of patients at risk for stroke with nonvalvular atrial fibrillation. J Am Coll Cardiol 2013; 61(17):1790-8.
  5. Andrade JG, Macle L, Nattel S, et al. Contemporary atrial fibrillation management: a comparison of the current AHA/ACC/HRS, CCS, and ESC guidelines. Can J Cardiol. Aug 2017; 33(8):965-976.
  6. Bajaj NS, Kalra R, Patel N, et al. Comparison of approaches for stroke prophylaxis in patients with nonvalvular atrial fibrillation: network meta-analyses of randomized controlled trials. PLoS One. 2016; 11(10):e0163608.
  7. Baman, JJ, Mansour, MM, Heist, EE, Huang, DD, Biton, YY. Percutaneous left atrial appendage occlusion in the prevention of stroke in atrial fibrillation: a systematic review. Heart Fail Rev, 2018 Feb 18;23(2). 
  8. Bartus K, Bednarek J, Myc J et al. Feasibility of closed-chest ligation of the left atrial appendage in humans. Heart Rhythm 2011; 8(2):188-93.
  9. Bartus K, Han FT, Bednarek J et al. Percutaneous left atrial appendage suture ligation using the LARIAT device in patients with atrial fibrillation: initial clinical experience. J Am Coll Cardiol 2013 Jul 9; 62(2):108-18.
  10. Blue Cross and Blue Shield Association. Technology Evaluation Center (TEC). Percutaneous left atrial appendage closure therapy for prevention of stroke. TEC Assessments 2014; Volume 29, Tab TBA.
  11. Bode WD, Patel N, Gehi AK. Left atrial appendage occlusion for prevention of stroke in nonvalvular atrial fibrillation: a meta-analysis. J Interv Card Electrophysiol. Jun 2015; 43(1):79-89.
  12. Briceno DF, Villablanca P, Cyrille N, et al. Left Atrial Appendage Occlusion Device and Novel Oral Anticoagulants Versus Warfarin for Stroke Prevention in Nonvalvular Atrial Fibrillation: Systematic Review and Meta-Analysis of Randomized Controlled Trials. Circ Arrhythm Electrophysiol. Oct 2015; 8(5):1057-1064.
  13. Boersma LV, Schmidt B, Betts TR, et al. Implant success and safety of left atrial appendage closure with the WATCHMAN device: peri-procedural outcomes from the EWOLUTION registry. Eur Heart J. Jan 27 2016.
  14. Chatterjee S, Herrmann HC, Wilensky RL, et al. Safety and Procedural Success of Left Atrial Appendage Exclusion With the Lariat Device: A Systematic Review of Published Reports and Analytic Review of the FDA MAUDE Database. JAMA Intern Med. Jul 2015; 175(7):1104-1109.
  15. Cruz-Gonzalez I, Gonzalez-Ferreiro R, Freixa X, et al. Left atrial appendage occlusion for stroke despite oral anticoagulation (resistant stroke). Results from the Amplatzer Cardiac Plug registry. Rev Esp Cardiol (Engl Ed). Jan 2020; 73(1): 28-34.
  16. Danna P, Proietti R, Sagone A et al. Does left atrial appendage closure with a cardiac plug system reduce the stroke risk in nonvalvular atrial fibrillation patients? A single-center case series. Pacing Clin Electrophysiol 2013; 36(3):347-53.
  17. Dar T, Afzal M, Yarlagadda B, et al. Mechanical function of the left atrium is improved with epicardial ligation of the left atrial appendage: Insights from the LAFIT-LARIAT Registry. Heart Rhythm, 2018 Feb 27;15(7). 
  18. Darden D, Duong T, Du C, et al. Sex Differences in Procedural Outcomes Among Patients Undergoing Left Atrial AppendageOcclusion: Insights From the NCDR LAAO Registry. JAMA Cardiol. Nov 01 2021; 6(11): 1275-1284.
  19. Dukkipati SR, Kar S, Holmes DR, et al. Device-Related Thrombus After Left Atrial Appendage Closure. Circulation, 2018 May 13;138(9). 
  20. Fauchier L, Cinaud A, Brigadeau F, et al. Device-related thrombosis after percutaneous left atrial appendage occlusion for atrial fibrillation. J Am Coll Cardiol. 2018 Apr 10; 71 (14): 1528-1536.
  21. FDA. Left Atrial Appendage Occlusion (LAAO) Devices Potentially Associated with ProceduralOutcome Differences Between Women and Men: Letter to Health Care Providers. 
  22. FDA. Approval Letter: WATCHMAN LAA Closure Technology. 2015; //www.accessdata.fda.gov/cdrh_docs/pdf13/p130013a.pdf.
  23. FDA. Summary of Safety and Effectiveness Data.  Amplatzer™ Amulet™ Left Atrial Appendage Occluder; 2021. https://www.accessdata.fda.gov/cdrh_docs/pdf20/P200049B.pdf.
  24. FDA. Summary of Safety and Effectiveness Data. WATCHMAN Left Atrial Appendage Closure Devicewith Delivery System and WATCHMAN FLX Left Atrial Appendage Closure Device with Delivery System. https://www.accessdata.fda.gov/cdrh_docs/pdf13/P130013S035B.pdf.
  25. Fink T, Schlüter M, Tilz R, et al. Acute and long-term outcomes of epicardial left atrial appendage ligation with the second-generation LARIAT device: a high-volume electrophysiology center experience. Clin Res Cardiol, 2018 Jun 9;107(12).
  26. Gafoor S, Franke J, Bertog S, et al. Left atrial appendage occlusion in octogenarians: short-term and 1-year follow-up. Catheter Cardiovasc Interv, 2013 Nov 22;83(5).
  27. Galea R, De Marco F, Meneveau N, et al. Amulet or Watchman Device for Percutaneous Left Atrial Appendage Closure:Primary Results of the SWISS-APERO Randomized Clinical Trial. Circulation. Mar 08 2022; 145(10): 724-738.
  28. Gloekler S, Shakir S, Doblies J, et al. Early results of first versus second generation Amplatzer occluders for left atrial appendage closure in patients with atrial fibrillation. Clin Res Cardiol. Aug 2015; 104(8):656-665.
  29. Gopinathannair R, Chen LY, Chung MK, et al. Managing Atrial Fibrillation in Patients With Heart Failure and Reduced Ejection Fraction: A Scientific Statement From the American Heart Association. Circ Arrhythm Electrophysiol. Jun 2021; 14(6): HAE0000000000000078.
  30. Guerios EE, Schmid M, Gloekler S et al. Left atrial appendage closure with the Amplatzer cardiac plug in patients with atrial fibrillation. Arq Bras Cardiol 2012; 98(6):528-36.
  31. Hanif H, Belley-Cote EP, Alotaibi A, et al. Left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation: a systematic review and network meta-analysis of randomized controlled trials. J Cardiovasc Surg (Torino). Feb 17 2017.
  32. Hildick-Smith D, Landmesser U, Camm AJ, et al. Left atrial appendage occlusion with the Amplatzer Amulet device: full resultsof the prospective global observational study. Eur Heart J. Aug 07 2020; 41(30): 2894-2901.
  33. Holmes DR, Doshi SK, Kar S, et al. Left atrial appendage closure as an alternative to warfarin for stroke prevention in atrial fibrillation a patient-level meta-analysis. J Am Coll Cardiol. 2015; 65(24):2614-2623.
  34. Holmes DR, Jr., Kar S, Price MJ, et al. Prospective randomized evaluation of the Watchman Left Atrial Appendage Closure device in patients with atrial fibrillation versus long-term warfarin therapy: the PREVAIL trial. J Am Coll Cardiol. Jul 8 2014; 64(1):1-12.
  35. Horstmann S, Zugck C, Krumsdorf U et al. Left atrial appendage occlusion in atrial fibrillation after intracranial hemorrhage. Neurology 2014; 82(2):135-8.
  36. IOM (Institute of Medicine). 2011. Clinical Practice Guidelines We Can Trust. Washington, DC: The National Academies Press.
  37. January CT, Wann LS, Alpert JS et al. 2014 AHA/ACC/HRS Guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol 2014.
  38. January C, Wann L, Calkins H, et al. 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Heart Rhythm, 2019 Feb 1. 
  39. Jazayeri MA, Vuddanda V, Turagam MK, et al. Safety profiles of percutaneous left atrial appendage closure devices: An analysis of the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database from 2009 to 2016. J. Cardiovasc. Electrophysiol., 2017 Oct 11;29(1).
  40. Kefer J, Vermeersch P, Budts W, et al. Transcatheter left atrial appendage closure for stroke prevention in atrial fibrillation with Amplatzer cardiac plug: the Belgian Registry. Acta Cardiol. Dec 2013; 68(6):551-558.
  41. Lakkireddy D, Afzal MR, Lee RJ, et al. Short and long-term outcomes of percutaneous left atrial appendage suture ligation: Results from a US multicenter evaluation. Heart Rhythm. May 2016; 13(5):1030-1036.
  42. Lakkireddy D, Thaler D, Ellis CR, et al.  Amplatzer amulet left atrial appendage occluder versus watchman device for stroke prophylaxis (Amulet IDE). Circulation. 2021 Nov9; 144(19):1543-1552.
  43. Lam YY, Yip GW, Yu CM et al. Left atrial appendage closure with Amplatzer cardiac plug for stroke prevention in atrial fibrillation: initial Asia-Pacific experience. Catheter Cardiovasc Interv 2012; 79(5):794-800.
  44. Landmesser U, Schmidt B, Nielsen-Kudsk J, et al. Left atrial appendage occlusion with the AMPLATZER Amulet device: periprocedural and early clinical/echocardiographic data from a global prospective observational study. EuroIntervention, 2017 Jun 27;13(7). 
  45. Landmesser U, Tondo C, Camm J, et al. Left atrial appendage occlusion with the AMPLATZER Amulet device: one-year follow-up from the prospective global Amulet observational registry. EuroIntervention, 2018 May 29;14(5).
  46. Li X, Wen SN, Li SN, et al. Over 1-year efficacy and safety of left atrial appendage occlusion versus novel oral anticoagulants for stroke prevention in atrial fibrillation: A systematic review and meta-analysis of randomized controlled trials and observational studies. Heart Rhythm. Dec 24 2015.
  47. Lip GY, Lane DA. Stroke prevention in atrial fibrillation: a systematic review. JAMA. May 19 2015; 313(19):1950-1962.
  48. Lip GY, Frison L, Halperin JL, et al. Comparative validation of a novel risk score for predicting bleeding risk in anticoagulatedpatients with atrial fibrillation: the HAS-BLED (Hypertension, Abnormal Renal/Liver Function, Stroke, Bleeding History orPredisposition, Labile INR, Elderly, Drugs/Alcohol Concomitantly) score. J Am Coll Cardiol. Jan 11 2011; 57(2): 173-80.
  49. Lip GYH, Banerjee A, Boriani G, et al. Antithrombotic Therapy for Atrial Fibrillation: CHEST Guideline and Expert Panel Report. Chest. Nov 2018; 154(5): 1121-1201.
  50. Litwinowicz R, Bartus M, Burysz, et al. Long term outcomes after left atrial appendage closure with the LARIAT device-Stroke risk reduction over five years follow-up. PLoS ONE, 2018 Dec 20;13(12).
  51. Litwinowicz R, Bartus M, Kapelak, et al. Reduction in risk of stroke and bleeding after left atrial appendage closure with LARIAT device in patients with increased risk of stroke and bleeding: Long term results. Catheter Cardiovasc Interv, 2019 Mar 19.
  52. Litwinowicz R, Bartus M, Malec-Litwinowicz M, et al. Left Atrial Appendage Occlusion for Secondary Stroke Prevention in Patients with Atrial Fibrillation: Long-Term Results. Cerebrovasc Dis. 2019; 47(3-4): 188-195.
  53. Lopez-Minguez JR, Eldoayen-Gragera J, Gonzalez-Fernandez R et al. Immediate and one-year results in 35 consecutive patients after closure of left atrial appendage with the Amplatzer cardiac plug. Rev Esp Cardiol 2013; 66(2):90-97.
  54. Masoudi FA, Calkins H, Kavinsky CJ, et al. 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview. J Am Coll Cardiol. Sep 29 2015; 66(13):1497-1513.
  55. Massumi A, Chelu MG, Nazeri A et al. Initial experience with a novel percutaneous left atrial appendage exclusion device in patients with atrial fibrillation, increased stroke risk, and contraindications to anticoagulation. Am J Cardiol 2013 Mar 15; 111(6):869-73
  56. Matsuo Y, Sandri M, Mangner N et al. Interventional closure of the left atrial appendage for stroke prevention. Circ J 2014; 78(3):619-24.
  57. Meerkin D, Butnaru A, Dratva D et al. Early safety of the Amplatzer Cardiac Plug for left atrial appendage occlusion. Int J Cardiol 2013; 168(4):3920-5.
  58. Miller MA, Gangireddy SR, Doshi SK, et al. Multicenter study on acute and long-term safety and efficacy of percutaneous left atrial appendage closure using an epicardial suture snaring device. Heart Rhythm, 2014 Jul 30;11(11).
  59. Montenegro MJ, Quintella EF, Damonte A et al. Percutaneous occlusion of left atrial appendage with the Amplatzer Cardiac PlugTM in atrial fibrillation. Arq Bras Cardiol 2012; 98(2): 143-50.
  60. Mou L, Norby FL, Chen LY, et al. Lifetime Risk of Atrial Fibrillation by Race and Socioeconomic Status: ARIC Study(Atherosclerosis Risk in Communities). Circ Arrhythm Electrophysiol. Jul 2018; 11(7): e006350.
  61. Nielsen-Kudsk JE, Korsholm K, Damgaard D, et al. Clinical Outcomes Associated With Left Atrial Appendage Occlusion VersusDirect Oral Anticoagulation in Atrial Fibrillation. JACC Cardiovasc Interv. Jan 11 2021; 14(1): 69-78.
  62. Nietlispach F, Gloekler S, Krause R et al. Amplatzer left atrial appendage occlusion: Single center 10-year experience. Catheter Cardiovasc Interv 2013 Aug 1; 82(2):283-9.
  63. Noelck N, Papak J, Freeman M, et al. Effectiveness of left atrial appendage exclusion procedures to reduce the risk of stroke: a systematic review of the evidence. Circ Cardiovasc Qual Outcomes. Jul 2016; 9(4):395- 405.
  64. Osmancik P, Herman D, Neuzil P, et al. Left Atrial Appendage Closure Versus Direct Oral Anticoagulants in High-Risk PatientsWith Atrial Fibrillation. J Am Coll Cardiol. Jun 30 2020; 75(25): 3122-3135.
  65. Park JW, Bethencourt A, Sievert H et al. Left atrial appendage closure with Amplatzer cardiac plug in atrial fibrillation: initial European experience. Catheter Cardiovasc Interv 2011; 77(5):700-6.
  66. Pisters R, Lane DA, Nieuwlaat R, et al. A novel user-friendly score (HAS-BLED) to assess 1-year risk of major bleeding in patients with atrial fibrillation: the Euro Heart Survey. Chest. Nov 2010; 138(5):1093-1100.
  67. Price MJ, Gibson DN, Yakubov SJ, et al. Early safety and efficacy of percutaneous left atrial appendage suture ligation: results from the U.S. transcatheter LAA ligation consortium. J Am Coll Cardiol. Aug 12 2014; 64(6):565-572.
  68. Price MJ, Reddy VY, Valderrabano M, et al. Bleeding outcomes after left atrial appendage closure compared with long-term warfarin: a pooled, patient-level analysis of the WATCHMAN randomized trial experience. JACC Cardiovasc Interv. Dec 28 2015; 8(15):1925-1932.
  69. Reddy VY, Doshi SK, Kar S, et al. 5-year outcomes after left atrial appendage closure: from the PREVAIL and PROTECT AF Trials. J Am Coll Cardiol. Dec 19 2017; 70(24):2964-2975.
  70. Reddy VY, Möbius-Winkler S, Miller MA et al. Left atrial appendage closure with the watchman device in patients with a contraindication for oral anti-coagulation: the ASAP study (ASA Plavix feasibility study with Watchman Left Atrial Appendage closure technology). J Am Coll Cardiol 2013; 61(25):2551-56.
  71. Reddy VY, Doshi SK, Sievert H et al. Percutaneous left atrial appendage closure for stroke prophylaxis in patients with atrial fibrillation: 2.3-year follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for embolic protection in patients with atrial fibrillation) trial. Circulation 2013; 127(6):720-9.
  72. Reddy VY, Holmes D, Doshi SK et al. Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for embolic protection in patients with AF (PROTECT-AF) clinical trial and the Continued Access Registry. Circulation 2011; 123(4):417-24.
  73. Reddy VY, Sievert H, Halperin J, et al. Percutaneous left atrial appendage closure vs warfarin for atrial fibrillation: a randomized clinical trial. JAMA. Nov 19 2014; 312(19):1988-1998.
  74. Sahay S, Nombela-Franco L, Rodes-Cabau J, et al. Efficacy and safety of left atrial appendage closure versus medical treatment in atrial fibrillation: a network meta-analysis from randomised trials. Heart. Jan 15 2017; 103(2):139-147.
  75. Santoro G, Meucci F, Stolcova M, et al. Percutaneous left atrial appendage occlusion in patients with non-valvular atrial fibrillation: implantation and up to four years follow-up of the AMPLATZER Cardiac Plug. EuroIntervention. Oct 30 2014.
  76. Stone D, Byrne T, Pershad A. Early results with the LARIAT device for left atrial appendage exclusion in patients with atrial fibrillation at high risk for stroke and anticoagulation. Catheter Cardiovasc Interv 2013.
  77. Streb W, Szymala M, Kukulski T et al. Percutaneous closure of the left atrial appendage using the Amplatzer Cardiac Plug in patients with atrial fibrillation: evaluation of safety and feasibility. Kardiol Pol 2013; 71(1):8-16.
  78. Swaans MJ, Post MC, Rensing BJ et al. Percutaneous left atrial appendage closure for stroke prevention in atrial fibrillation. Neth Heart J 2012; 20(4): 161-6.
  79. Takeda K, Tsuboko Y, Iwasaki K. Latest outcomes of transcatheter left atrial appendage closure devices and direct oralanticoagulant therapy in patients with atrial fibrillation over the past 5 years: a systematic review and meta-analysis. CardiovascInterv Ther. Jan 30 2022.
  80. Tereshchenko LG, Henrikson CA, Cigarroa J, et al. Comparative effectiveness of interventions for stroke prevention in atrial fibrillation: a network meta-analysis. J Am Heart Assoc. May 20 2016; 5(5).
  81. Urena M, Rodes-Cabau J, Freixa X et al. Percutaneous left atrial appendage closure with the AMPLATZER cardiac plug device in patients with nonvalvular atrial fibrillation and contraindications to anticoagulation therapy. J Am Coll Cardiol 2013; 62(2):96-102.
  82. Wei Z, Zhang X, Wu H, et al. A meta-analysis for efficacy and safety evaluation of transcatheter left atrial appendage occlusion in patients with nonvalvular atrial fibrillation. Medicine (Baltimore). Aug 2016; 95(31):e4382.
  83. Wiebe J, Bertog S, Franke J et al. Safety of percutaneous left atrial appendage closure with the amplatzer cardiac plug in patients with atrial fibrillation and contraindications to anticoagulation. Catheter Cardiovasc Interv 2013.

POLICY HISTORY:

Medical Policy Group, December 2011 (3)

Medical Policy Administration Committee, December 2011

Available for comment December 14, 2011 through January 27, 2012

Medical Policy Group, March 2012 (3): 2012 Updates to Description, Key Points & References

Medical Policy Panel, March 2013

Medical Policy Group, June 2013 (4): 2013 Updates to Description, Key Points, Key Words & References; no change in policy statement

Medical Policy Panel, July 2014

Medical Policy Panel, July 2014 (4): Updated Description, updated Key Points to include Practice Guidelines, updated Approved Governing Bodies and References.  There were no changes to the policy at this time.

Medical Policy Group, May 2015 (4):  Update to Approved Governing Bodies

Medical Policy Panel, October 2015

Medical Policy Group, December 2015 (4): Updates to Description, Key Points, Approved Governing Bodies, and References. No change to policy statement.

Medical Policy Panel, May 2016

Medical Policy Group, June 2016 (4): Updates to Key Points and References.  No change to policy statement.

Medical Policy Group, December 2016: 2017 Annual Coding Update. Created Previous Coding section and moved deleted code 0281T to this section. Added new CPT code 33340 to Current Coding.

Medical Policy Panel, May 2017

Medical Policy Group, May 2017 (4): Updates to Description, Key Points, Key Words and References.  No change to policy statement.

Medical Policy Panel, 2018

Medical Policy Group, May 2018 (4): Updates to Description, Key Points, Approved by Governing Bodies, and References.  No change to policy statement.

Medical Policy Group June 2018: Clarified policy statement to include other devices and routes.

Medical Policy Administration Committee, June 2018

Available for comment June 14 through July 28, 2018

Medical Policy Panel, May 2019

Medical Policy Group, June 2019 (4): Updates to Description, Policy, Key Points, and References.  Updated policy statements to allow coverage for FDA approved LAAs with criteria.

Medical Policy Administrative Committee: June 2019

Available for Comment: June 11, 2019 through July 29, 2019

Medical Policy Panel, May 2020

Medical Policy Group, June 2020 (4): Updates to Key Points and References. No change to policy statements.

Medical Policy Panel, May 2021

Medical Policy Group, June 2021: Updates to Description, Key Points, Approved by Governing Bodies, and References.  Policy statement updated to remove “not medically necessary,” no change to policy intent.

Medical Policy Group, November 2021: 2022 Annual Coding Update.  Added CPT code 33999 and new CPT code 33269 to current coding section.  Removed Previous coding section and code 0281T.  Clarified policy section by adding LAA clipping policy statement and removed specific devices from coverage statement.  Added updated information regarding the Amulet device FDA approval.  Removed the Amulet from the IV statement.  Additional updates to Key Points, Approved by Governing Bodies and References.

Medical Policy Group, March 2022 (4): Clarification to policy statement by adding “Percutaneous and other stand alone procedures” for epicardial clipping are IV.  No change to policy intent.

Medical Policy Panel, May 2022

Medical Policy Group, May 2022 (4): Updates to Description, Key Points, Approved by Governing Bodies, and References.  Old references removed.  No change to policy statements.

Medical Policy Group, August 2022 (4): Removed information related to epicardial clipping.  CPT codes 33269 and 33999 removed.  See new medical policy 751.

Medical Policy Panel, May 2023

Medical Policy Group, May 2023 (4): Updates to Description, Key Points, Governing Bodies, Practice Guidelines, Key Words (Amplatzer Cardiac Plug device, WaveCrest) Benefit Application and References.

This medical policy is not an authorization, certification, explanation of benefits, or a contract. Eligibility and benefits are determined on a case-by-case basis according to the terms of the member’s plan in effect as of the date services are rendered. All medical policies are based on (i) research of current medical literature and (ii) review of common medical practices in the treatment and diagnosis of disease as of the date hereof. Physicians and other providers are solely responsible for all aspects of medical care and treatment, including the type, quality, and levels of care and treatment.

This policy is intended to be used for adjudication of claims (including pre-admission certification, pre-determinations, and pre-procedure review) in Blue Cross and Blue Shield’s administration of plan contracts.

The plan does not approve or deny procedures, services, testing, or equipment for our members. Our decisions concern coverage only. The decision of whether or not to have a certain test, treatment or procedure is one made between the physician and his/her patient. The plan administers benefits based on the member’s contract and corporate medical policies. Physicians should always exercise their best medical judgment in providing the care they feel is most appropriate for their patients. Needed care should not be delayed or refused because of a coverage determination.

As a general rule, benefits are payable under health plans only in cases of medical necessity and only if services or supplies are not investigational, provided the customer group contracts have such coverage.

The following Association Technology Evaluation Criteria must be met for a service/supply to be considered for coverage:

1. The technology must have final approval from the appropriate government regulatory bodies;

2. The scientific evidence must permit conclusions concerning the effect of the technology on health outcomes;

3. The technology must improve the net health outcome;

4. The technology must be as beneficial as any established alternatives;

5. The improvement must be attainable outside the investigational setting.

Medical Necessity means that health care services (e.g., procedures, treatments, supplies, devices, equipment, facilities or drugs) that a physician, exercising prudent clinical judgment, would provide to a patient for the purpose of preventing, evaluating, diagnosing or treating an illness, injury or disease or its symptoms, and that are:

1. In accordance with generally accepted standards of medical practice; and

2. Clinically appropriate in terms of type, frequency, extent, site and duration and considered effective for the patient’s illness, injury or disease; and

3. Not primarily for the convenience of the patient, physician or other health care provider; and

4. Not more costly than an alternative service or sequence of services at least as likely to produce equivalent therapeutic or diagnostic results as to the diagnosis or treatment of that patient’s illness, injury or disease.